Load Cell : C2D1 series[29 Oct. 2009, 19:29:03]
* High capacity and applicable for commercial scale.
* Because the output voltage is adjusted, it is available in both single point / multipoint.
Specifications
Rated capacity 980.7 N { 100 kgf} ~ 7.845 kN { 800 kgf}
Safe overload 150 % R.C.
Ultimate overload 200 % R.C.
Rated output 2 mV/ V( 0.004, -0) mV/ V
Non-linearity 0.02 % R.O.
Hysteresis 0.02 % R.O.
Repeatability 0.02 % R.O.
Creep 0.025 % R.O./ 20 min
Creep recovery 0.025 % R.O./ 20 min
Excitation, recommended 12 V or less
Excitation, maximum 16 V
Zero balance ± 0.1 mV/ V
Input resistance 420 © ± 40 ©
Output resistance 350 © ± 3 ©
Insulation resistance 2 000 M© or more ( DC50 V) ( between bridge and main body)
Temp. range, compensated -10 ~ 50
Temp. range, safe -20 ~ 70
Temp. effect on zero 0.05 % R.O./ 10
Temp. effect on output 0.02 % LOAD/ 10
Cable Æ 6.3, 4-cores shielded 6 m cable directly attached, Y-crimp type terminal lugs are attached at cable end.
Class of protection IP65
Material of element Alluminium alloy
Durability 1 000 000 times with rated load applied.
Effect of eccentric load e The size of loading plate : 450 mm x 650 mm at maximum.
e The center of loading plate and also the center of load cell should be the same position.
e Error is within 0.02 % R.O. applied with 1/ 2 of rated capacity at the position of 200 mm of eccentricity.